       RAD-Check Micro-R X-Ray Test Instrument.       


Fluke Biomedical, Inc. Key Features

  • Entrance skin exposure measurements (ESE)
  • Fluoroscopy exposure examinations
  • Exposure checks; radiographic (mR/mAs)
  • Beam quality; half value layer (HVL)
  • mAs reciprocity; mA station checks…plus many others, depending on the remote external chambers used
  • The American College of Radiology (ACR) recommends this type of product in their quality assurance program
  • Fast and easy to use
  • Dual-range for high and low dose rate fluoroscopy
  • Optimized for use with our 100 cm³ Image Intensifier Ion Chamber (Model 06-524-3000)
  • Portable, no AC power cords

  • Introduction
    This state-of-the-art electrometer is designed for measuring dose and rate under high and low dose rate conditions. It is excellent for cardiac cath and fluoroscopy and the perfect choice for tight budgets. Victoreen® RAD-CHECK® MICRO-R technology gives you the ability to measure dose and rate in fluoroscopy with the accuracy and reliability of equipment that costs two or three times more.

    Applications
    With the RAD-CHECK MICRO-R, measurements are easy to perform and highly accurate. Incorporate RAD-CHECK MICRO-R into


    your routine QC program for fluoroscopy now, and accurately measure what your patient exposures actually are from fluoroscopically guided procedures. This precision electrometer also features a tilt-stand for convenient adjustment of display visibility.

    Specifications

    Ranges Low: 0.01 to 19.99 mR; 0.1 to 199.9 R/min, High: 0.01 to 19.99 R; 0.1 to 1999 R/min
    Standard calibration At 75 kVp with 4 mm Al filtration at 22°C and one atmosphere using Model 06-524-3000 chamber
    Reproducibility Within 2% short-term over 100 mR to 2 R range (1 to 20 mGy)
    Maximum exposure rate Minimum 90% collection at 20 R/sec
    Electrometer drift Low Range: 1 mR/min typical; 6 mR/min maximum, High Range: 10 μR/min typical; 60μR/min maximum
    Manual reset Resets display to zero
    Operating temperature 50º to 104ºF (10º to 40°C)
    Relative humidity 0 to 90%
    Display 3.50 x 0.50 inch LCD, low battery indicator
    Control Reset button, dose or dose rate output selector, high or low range selector, on/off switch
    Power requirements 9 V alkaline battery, > 50 hour life
    Dimensions 6 (w) x 6.25 (d) x 2.75 in (h) (15.25 x 6.25 x 7 cm)
    Weight 1.125 lb (0.51 kg)

    NOTE: Units must have Model 06-524-3000 chamber and must be calibrated at the same time.


    Stock #
    Description
    Your Price
    06-526-5240
    RAD-CHECK MICRO-R
    $2,248.91
    06-526-5242
    RAD-CHECK MICRO-R, Sl Units
    $1,597.89
    89-525
    Carrying/Storage Case (Holds
    RAD-CHECK MICRO-R and Accessories)
    $190.84
    06-524-3000
    100 cm³ Image Intensifier Ion Chamber
    $1,799.84







    Cards We Accept!
    For order methods and policies, please click here.


    E-Mail Sales
    Telephone
    All Lines open 8-5 M-F (Pacific Time)
    Toll-Free (US): 800-827-XRAY (800-827-9729)
    Toll-Free (US): 866-PNW-XRAY (866-769-9729)
    Normal: 1-503-667-3000
    VoIP Phones / Internet Phones...
    Free World Dial-Up: 52824
    Earthlink: 07393-52824
    SIPphone: 1-393-52824
    Packet8: 0351-52824
    Broadvoice: 0110393-52824
    Download our order form
    and then...Fax Your Order
    24 Hours a day!
    503-666-8855

    P.O. Box 625 * Gresham, OR  97030 * U.S.A.

    This web site is our catalog, no printed catalog is available. - Please keep checking back, changes to this site are made daily.
    Every effort is made on our part to keep all posted prices up to date, however we can not guarantee the accuracy due to notification delays by the manufacturers.
    Purchase Orders accepted only upon approval of credit - Min. $500 opening order for new open CHARGE accounts.
    All other orders (Cash, Credit Card, etc) subject only to a $30 product minimum order!



    ©1997-2008 Pacific Northwest X-Ray Inc. - Sales & Marketing Division - All Rights Reserved