Pacific Northwest X-Ray Inc.

       Nuclear Medicine, Bar Resolution Test Phantoms.       


Biodex Inc! Determines Resolution of Scintillation Cameras

Four-quadrant Bar Phantoms offer precise determination of camera intrinsic resolution, collimator spatial resolution, field size and linearity. Biodex offers a full range of sizes manufactured to the highest quality standards.

NOTE: *243-986 Bar Phantom, Symbia and E-Cam - Includes two removable screw knobs for insertion/removal of phantom from camera head.

Manual for this product is available.

Rectangular Bar Phantom: 243-935
Dimensions: 22.25" l x 17" w x .5" h (56.5 x 43.2 x 1.27 cm)
Lead Bar Widths: .079", .098", .118" and .138" (2, 2.5, 3 and 3.5 mm)
Field Across Bar Configurations: 21" l x 15.9" w (53.3 x 40.5 cm)
Shipping Weight: 21 lb (10 kg)

Standard Bar Phantom: 243-850
Dimensions: 16.875" l x 16.875" w x .5" h (43 x 43 x 1.27 cm)
Lead Bar Widths: .25", 187", .156", and .375"(6.4, 4.8, 4 and 9.5 mm)
Field Across Bar Configurations: 15.875" l x 15.875" w (40.3 x 40.3 cm)
Shipping Weight: 14 lb (6 kg)



Bar Phantom, Standard, High Resolution: 243-850
Dimensions: 16.875" l x 16.875" w x .5" h (43 x 43 x 1.28 cm)
Lead Bar Widths: .25", .187", .156", and .125" (6.4, 4.8, 4 and 3.2 mm)
Field Across Bar Configurations: 15.875" l x 15.875" w (40.3 x 40.3 cm)
Shipping Weight: 14 lb (6 kg)

Triple Head Rectangular Bar Phantom: 243-975
Dimensions: 11" l x 18" w x .5" h (28 x 45.7 x 1.27 cm)
Lead Bar Widths: .079", .098", .118" and .138" (2, 2.5, 3 and 3.5 mm)
Field Across Bar Configurations: 10" l x 17" w (25.4 x 43.2 cm)
Shipping Weight: 19 lb (8.7 kg)

Symbia and E-CAM Bar Phantom: 243-986
Includes two removable screw knobs for insertion/removal of phantom from camera head.
Dimensions: 16" l x 21.4" w x .5" h (40.6 x 54.4 x 1.27 cm)
Lead Bar Widths: .079", .098", .118" and .138" (2, 2.5, 3 and 3.5 mm)
Field Across Bar Configurations: 20.3" l x 14.875" w (51.6 x 37.8 cm)
Shipping Weight: 19 lb (8.7 kg)

Cardiac Bar Phantom: 243-955
Dimensions: 15.5" l x 9.25" w x .5" h (39.4 x 23.5 x 1.27 cm)
Lead Bar Widths: .079", .098", .118" and .138" (2, 2.5, 3 and 3.5 mm)
Field Across Bar Configurations: 14.5" l x 8.25" w (36.8 x 21 cm)
Shipping Weight: 15 lb (6.80 kg)


Stock #
Description
Dimensions
Lead Bar Widths
Field Across Bar Configurations
Shipping Weights
Your Price
243-935
Bar Phantom, Rectangular
22.25" L x 17" W x .5" H
(56.5 x 43.2 x 1.27 cm)
.079", .098", .118" and .138"
(2, 2.5, 3 and 3.5 mm)
21" L x 15.9" W
(53.3 x 40.5 cm)
21 lb (10 kg)
$1,353.46
243-850
Bar Phantom, Standard
16.875" L x 16.875" W x .5" H
(43 x 43 x 1.27 cm)
.25", 187", .156", and .375"
(6.4, 4.8, 4 and 9.5 mm)
15.875" L x 15.875" W
(40.3 x 40.3 cm)
14 lb (6 kg)
$1,353.46
243-800
Bar Phantom, Standard,
High Resolution
16.875" L x 16.875" W x .5" H
(43 x 43 x 1.28 cm)
.25", .187", .156", and .125"
(6.4, 4.8, 4 and 3.2 mm)
15.875" L x 15.875" W
(40.3 x 40.3 cm)
14 lb (6 kg)
$1,353.46
243-975
Bar Phantom, Rectangular,
Triple Head
11" L x 18" W x .5" H
(28 x 45.7 x 1.27 cm)
.079", .098", .118" and .138"
(2, 2.5, 3 and 3.5 mm)
10" L x 17" W
(25.4 x 43.2 cm)
19 lb (8.7 kg)
$1,353.46
243-986
*Bar Phantom, Symbia
and E-Cam
16" L x 21.4" W x .5" H
(40.6 x 54.4 x 1.27 cm)
.079", .098", .118" and .138"
(2, 2.5, 3 and 3.5 mm)
20.3" L x 14.875" W
(51.6 x 37.8 cm)
19 lb (8.7 kg)
$1,353.46
243-955
Bar Phantom, Cardiac,
High Resolution
15.5" L x 9.25" W x .5" H
(39.4 x 23.5 x 1.27 cm)
.079", .098", .118" and .138"
(2, 2.5, 3 and 3.5 mm)
14.5" L x 8.25" W
(36.8 x 21 cm)
15 lb (6.80 kg)
$1,353.46




       Nuclear Medicine, Flood Phantom.       
Biodex Inc! Flood Phantom.
Determines Field Uniformity of Scintillation Cameras by providing a means of lighting scintillation camera's crystal to determine response uniformity over the entire field. Biodex Flood Phantoms feature extra strength side walls and clear lucite for easy positioning. Easy to fill and easy to drain, the phantoms are leak proof and are excellent for transmission imaging.

Dimensions: 20.5" x 28" x 1.25" thick (52 x 71.1 x 3.2 cm)
Cavity: 16.5" x 24" x .5" (41.9 x 60.9 x 1.3 cm)


Phantom Funnel.
Screws directly into the flood phantom for safe, easy, fast filling.

Manual for this product is available.


Stock #
Description
Your Price
043-054
Flood Phantom, Rectangular
$873.85
131-010
Phantom Funnel, Flood
$39.00






       Nuclear Medicine, Thyroid Uptake Neck Phantom.       


Biodex Inc! A Must for Every Department Performing Thyroid Uptakes!

The Neck Phantom is designed to simulate a patient's neck. The phantom is constructed of lucite. It has a two part insert that allows counting from a bottle, vial or capsule. A capsule holder is supplied to enable the user to count capsules directly, without having to dissolve them. The phantom's cylinder and carrier have scribelines for accurate alignment. A flat surface on the cylinder allows either vertical or horizontal positioning. Twelve 30 ml bottles are included with the phantom.

Proposed by the International Atomic Energy Agency (I.A.E.A.) and the American National Standards Institute.

Dimensions: 5" h x 5" dia (127 x 127 cm)
I.D.: 4" h x 2" dia (10 x 5 cm)

Manual for this product is available!


Stock #
Description
Your Price
043-365
Thyroid Uptake Neck Phantom
(Complete with Bottle Carrier, Capsule Holder and 12 Polyethylene bottles)
$609.23
043-361
Polyethylene Bottles, 30 ml, 50/pkg
$182.77




       Nuclear Medicine, Triple Line Insert.       
Biodex Inc! The Triple Line Insert is used to produce three 1 mm diameter parallel lines of tracer material spaced 7.5 cm apart. The locations of the fillable tubes are based on the recommendations in the NEMA Standards Publication for Performance Measurements of Scintillation Cameras, 1986.

Radioactive tracer liquid can be inserted into the line sources through surgical grade, stainless steel valves located at the ends of each line tube.

The cylinder can be filled with water to simulate the surrounding attenuating medium.

Quantitative measurements of on-axis and off-axis reconstructed line source resolutions can be performed in air by placing the triple line insert directly on the scanning bed.

The triple line insert provides accurate, reproducible images to quantitatively evaluate the effects of errors in center-of-rotation and radius-of-rotation on scanners. Using the insert, the influence of the type of reconstruction filter on SPECT spatial resolution measurements can be evaluated.

Features:
-Center-of-rotation error evaluation.
-Evaluation of changes of radius-of-rotation on spatial resolution.
-Spatial resolution measurement in air and in water, if mounted in cylinder.
-Quantitative evaluation of reconstruction filters and scatter compensation method.

Specifications:
-Useful Height of Line Sources: 2.76" (7 cm)
-Diameter of Insert: 7.3" (18.6 cm)
-Diameter of Line Sources: ~1 mm
-Spacing of Line Sources: 2.95" (7.5 cm)
-Shipping Weight: 3 lb (1.3 kg)




Stock #
Description
Your Price
043-730
Phantom Insert, Triple Line
$1,294.62
043-765
Phantom, SPECT, Flangeless
$3,182.14
043-772
Phantom, PET, SPECT, ACR
$4,191.43
043-750
Phantom, SPECT, Deluxe
$3,053.57
043-762
Phantom, SPECT, Standard
$2,700.00
043-740
Phantom, Lung-Spine
$5,001.43




       Nuclear Medicine, Cardiac Insert.       


Biodex Inc! This insert provides a multi-function simulation of the left ventricle, and can be used to evaluate SPECT imaging of cold defects within the "myocardium." Two solid acrylic sectors (45 and 60 degrees) are supplied with the insert, each one cm thick and two cm long. These non-filling defects may be placed at various positions within the "ventricle wall", either anteriorly or posteriorly. The long axis of the "ventricle" is adjustable from 30 to 60 degrees from the long axis of the cylinder. Four fillable defects are also included.

Features:
-Evaluation of cardiac ECT data.
-Evaluation of attenuation and scatter.
-Simulates normal and abnormal myocardial uptake.
-Solid inserts simulate transmural and non-transmural cold abnormalities.
-Fillable inserts simulate transmural and non-transmural cold or hot abnormalities.
Specifications:
-"Ventricle" Overall Dimensions: 3.7" l x 2.4" dia (9.3 x 6.1 cm)
-"Ventricle" Volume: ~ 60 ml
-"Myocardium" Thickness: 0.4" (1.0 cm)
-"Myocardium" Volume: ~ 110 ml
-Solid Defect Set (three pieces):
- 60° x 2 cm (h) x 10 mm (thick)
- 45° x 1.53 cm (h) x 10 mm (thick)
- 60° x 2 cm, with 5 mm wall thickness (non-transmural defect)
-Fillable Defect Set (four pieces):
- 180° x 2 cm (h) x 10 mm (thick) / Vol ~ 13 ml
- 90° x 2 cm (h) x 10 mm (thick) / Vol ~ 5.4 ml
- 45°x 2 cm (h) x 10 mm (thick) / Vol ~ 3.8 ml
- 45° x 2 cm (h), with 5 mm thick chamber / Vol ~ 1.4 ml


Stock #
Description
Your Price
043-777
Phantom Insert, Cardiac
Includes: Defect Set
$2,436.43
043-765
Phantom, SPECT, Flangeless
$3,182.14
043-772
Phantom, PET, SPECT, ACR
$4,191.43
043-750
Phantom, SPECT, Deluxe
$3,053.57
043-762
Phantom, SPECT, Standard
$2,700.00
043-740
Phantom, Lung-Spine
$5,001.43
043-795
Phantom, Anthropomorphic Torso
$7,727.14




       Hoffman 3-D Brain Phantom™       
Biodex Inc! The Hoffman 3-D Brain Phantom provides the anatomically accurate three dimensional simulation of the radioisotope distribution found in the normal brain. The Phantom allows quantitative and qualitative study of the three dimensional effects of scatter attenuation as they would appear in Iodine123-IMP or Iodine123-HIPDM imaging with single photon emission computer tomography or fluorine-FDG-F18 imaging with positron emission computed tomography. The phantom simulates the 4:1 uptake ratio in the gray and white matter, normal in these studies. Ventricles that are normally void of radioactivity are present. The phantom is compromised of sturdy plastic and a single fillable chamber that eliminates the necessity of preparing different concentrations of radioisotope. Nineteen independent plates stack neatly within the cylindrical phantom for easy disassembly and assembly. The user can easily add his own custom defects to simulate clinical abnormalities.

The Phantom can be filled with the appropriate radioactive material or contrast material for SPECT, PET or MRI applications.

Each of 19 inserts is made up of five thinner slices. Two slices 0.03" thick interspersed in 0.6" thick slices to create a composite slice.

Specifications:
Cylinder Dimensions: I.D.: 6.9" h x 8.2" dia (17.5 x 20.8 cm)
Fillable Volume: ~ 1.2 L
Shipping Weight: 23 lb (10.4 kg)




Stock #
Description
Your Price
043-790
Phantom, Hoffman 3-D Brain
$14,091.43




       Nuclear Medicine, Hollow Spheres       


Biodex Inc! Description:
Designed for use in all circular and elliptical SPECT cylinders.
Simulates hot and cold spherical "lesions".
Quantitative evaluation of spatial resolution/object size, attenuation and scatter effects.
Evaluation of quantitative ECT reconstruction methods.

Specifications:
Set: Six hollow spheres (each individually removable and fillable)
Diameter: I.D.: 9.9 mm, 12.4 mm, 15.6 mm, 19.7 mm, 24.8 mm, and 31.2 mm
Volume of Spheres: 0.5 ml, 1.0 ml, 2.0 ml, 4.0 ml, 8.0 ml, and 16.0 mm


Stock #
Description
Your Price
043-763
Phantom, Hollow Spheres Set of six.
$1,391.54







Cards We Accept!
For order methods and policies, please click here.


E-Mail Sales
Telephone

Phone Lines open...
8am - 5pm Monday-Friday (Pacific/West Coast Time)
Toll-Free (US): 800-827-XRAY (800-827-9729)
Toll-Free (US): 866-PNW-XRAY (866-769-9729)
Skype: pnwxray
Phone: 1-503-667-3000
Download our order form
and then...Fax Your Order
24 Hours a day!
1-503-666-8855

P.O. Box 625 * Gresham, OR  97030 * U.S.A.

This web site is our catalog, no printed catalog is available. - Please keep checking back, changes to this site are made daily.
Every effort is made on our part to keep all posted prices up to date, however we can not guarantee the accuracy due to notification delays by the manufacturers.
Purchase Orders accepted only upon approval of credit - Min. $500 opening order for new open CHARGE accounts.
All other orders (Cash, Credit Card, etc) subject only to a $30 product minimum order!



©1997-2017 Pacific Northwest X-Ray Inc. - Sales & Marketing Division - All Rights Reserved