Specifications for Model 1060DA
Range: 5 decades, based on 1060AM-V
Operator interface: Radiation values display Digital, microprocessor controlled, intelligent display
Type: PLED, 16 x 2 matrix, 2 lines, 16 characters per line. Line 1 Displays radiation value and engineering
units. Line 2 Displays alarm messages (HIGH ALARM, OVERRANGE, JAM, FAIL)
Luminance: 350 cd/m2, min
Display size: 2.56 (w) x 0.63 in (h)
Character size: 0.20 in, typical (0.105 x 0.197 in)
Color: Yellow/Green
Value: Up to five digits with floating decimal point
Units: Auto ranging, mR/hr; SI
High alarm indicators
Visual: Red, High intensity LED
0.78 in Ř
Default setpoint is 2.0 mR/hr
Audible: 103 ± 5 db(A) siren at 15 VDC, 24 inches, 25°C. 2,900 ± 250 Hz operating frequency.
Stainless steel diaphragm.
Alarm: silence Single pole, push to make, momentary push button switch silences Audible alarm. Also initiates a
self-test routine when held for three (3) seconds
Enclosure:
Ingress protection IP65: DIN VDE 0470/EN 60529, up to NEMA 4
Enclosure dimensions: 7.5 (l) x 2.24 in (w) x 1.26 in (h) (approx.)
Overall: 8.9 in (l) x 3.42 in (w) x 1.88 in (h)
Weight: 0.85 lbs (Approximate)
Mounting: 4, adjustable foot mounting brackets provided
External connections
I/O cable: 6 conductor, 22 AWG, shielded cable interconnects digital display and alarm unit to 1060AM-V
controller (Model 50-113)
Mating connector: Switchraft EN3 Mini Weathertight connector supplied with unit (Model 32-122)
Max: length 50 feet
| 
|