Fluke Biomedical, Inc. The winning combination. The 35080M and 199XRAY are commonly used x-ray tools unmatched by traditional meters. This winning combination allows busy service engineers and biomedical personnel the ability to perform fast and accurate verification of kVp values for calibration or QA assessment. Fluke Biomedical is offering this combination in a convenient kit with all the accessories you need to get started.

199XRAY
  • ScopeMeter displays kVp wave forms and direct kVp values simultaneously on an easy-to-read screen.
  • No more time spent calculating scope traces to derive kVp values
  • Full medical oscilloscope scope functionality with color display
  • ScopeMeter triggers on standard interlaced and high-resolution, non-interlaced video systems. Triggers on all lines nonselectively or select an individual video line-up to 2800 lines per frame
  • mAs measurement calculates current over time
  • Smart averaging capabilities
  • Extended vertical offset
  • FlukeView* for Windows* for documenting, enhancing, waveform analysis, and archiving results.

  • The 199XRAY Medical ScopeMeter has all of the normal oscilloscope functions, as well as the speed, performance, and analysis power for the more demanding applications. This high-performance oscilloscope offers specifications found on top-end bench instruments. With up to 200 MHz bandwidth, 2.5 GS/s real-time sampling, and a deep memory of 27,500 points per input, the 199XRAY is ideal for engineers who need the full capabilities of a high-performance oscilloscope in a handheld, battery-powered instrument.

    In addition, the 199XRAY is especially designed for use with x-ray systems. This ScopeMeter displays kVp waveforms and direct kVp values simultaneously on an easy-to-read screen. Now you no longer have to waste time calculating scope traces to derive the kVp values.

    Specifications

    Field Applications
    Bandwidth Dual input: 200, 100 or 60 MHz
    Real-time sampling rate Up to 2.5 GS/s
    Trigger types Connect-and-View™ automatic triggering and a full range of manual trigger modes
    Extended video triggering Along with its triggering capability for standard, interlaced TV signals, the


    instrument also triggers on high-resolution, non-interlaced video systems. The ScopeMeter 199XRAY will trigger on all lines (nonselective), or can select an individual video line from systems with up to 2800 lines per frame.
    Persistence Digital persistence for analyzing complex dynamic waveforms, similar to an analog scope
    Selectable persistence Persistence mode with selectable decay time helps to find anomalies in the wave shape and optimizes the display for color information when working with composite color video.
    Display Fast-display update rate for seeing dynamic behavior instantaneously. Automatic capture and replay of 100 screens.
    Maximum record length 27,500 points-per-input record length using ScopeRecord mode.
    Trend analysis TrendPlot paperless chart recorder for trend analysis up to 22 days..
    independently floating isolated inputs Up to 1,000 V
    Waveform compare Waveform reference for visual comparisons and automatic pass/fail testing of waveforms.
    Vpwm Vpwm function for motor drive and frequency inverter applications.
    mA mAs measurement calculates current over time. Using the cursors, you can now measure directly the amount of radiation produced by x-ray systems, or the total amount of charge applied to a system.
    Smart averaging Smart averaging gives the averaged waveform over successive acquisitions, reducing noise in the displayed waveform. Thanks to smart averaging, you can now also see an incidental curve of a different wave shape with no effect on the averaged curve. This allows you to see the averaged curve of a sequence of video lines, for example, while still seeing the incidental flyback line flash by. The oscilloscope gives an immediate response when the signal makes large changes.
    Extended offset Vertical offset is now extended to a maximum of 16 divisions, allowing vertical zoom-in for study of small details of the signal.
    Electrical safety 1000 V CAT II and 600 V CAT III safety certified.
    Power requirements Rechargeable NiMH battery pack, four hours operation
    Dimensions (LxWxH) 25.6cm x 16.9cm x 6.4cm (l0.a in x 6.6 in x 2.5 in)
    Weight 2.0 kg (4.4 lb)

    MA190 Accessory Kit
    The MA190 accessory set enables interconnection of the Fluke 199XRAY for use in the field of Medical Imaging and Video systems. The kit is included in the Fluke 199XRAY as a standard. The accessory kit includes the following:
  • 50 Ω BNC feedthrough terminator, in insulated enclosure, to maintain proper termination of test connections during measurement
  • 50 Ω BNC terminator with 10:1 signal attenuation, to keep test terminal properly loaded while getting optimum signal amplitude to benefit from the instrument’s extended offset range
  • 1 Ω current shunt for current measurements, in insulated enclosure






  • Safety-designed BNC cable, 1.5 m (5 ft), with plastic connectors for safe connection to test terminals even when not at ground potential
  • Insulated BNC (f) to 4 mm banana-plug adapter
  • Dual 4 mm banana receptacles (1 red, 1 black)

  • Dimensions: 10.1 in L x 6.6 in W x 2.5 in H.(25.6 cm L x 16.9 W cm x 6.4 cm H)
    Weight: 4.4 lb (2 kg)

    FlukeView® forWindows

    Documenting
  • Transfer waveforms, screens, and measurement data from the ScopeMeter to a PC. Print or import the data into your report.
  • Enhancing
  • Add user text to individual ScopeMeter settings, providing guidance to the operator when recalling a setup.
  • Archiving
  • Create a library of waveforms with your comments for easy reference and comparison. Store complete replay cycles for analysis of waveform changes. Store complete memory content of theScopeMeter on your PC for backup purposes.
  • Waveform Comparison
  • Store reference waveforms, add operator instructions, and send both to the ScopeMeter for waveform comparison and “Pass/Fail” testing.
  • Analysis
  • Use cursors, perform spectrum analysis, or export data to other analysis programs.

  • 35080M
  • New miniaturized configuration for convenient transport to the job site
  • Fast/easy non-invasive kVp values for calibration/QA
  • Non-invasive technology eliminates the hazards of high-voltage cables and the need for bulky divider tanks
  • Auto ON/OFF when connected/disconnected
  • Optional filter packs enable testing in all modalities
  • Rh/Rh measurement capability when 35080M is used with Cadmium K-Edge and Linear Mammo Filter Pack Pair
  • Convenient storage/carrying case

  • 35080M Non-Invasive kVp Divider


    The 35080M Non-Invasive kVp Divider quickly and accurately measures kVp for all modalities. The unit checks both above and below table tubes and displays the direct kVp values on the 35050AT Dosimeter, the 199XRAY Medical ScopeMeter, or optional Excel Add-in software. The 35080M is highly portable and eliminates the need for bulky and heavy high-voltage divider tanks. In fact, it’s so compact in size that it fits into a shirt pocket.

    A patented* wide-range filter pack is included with the 35080M and provides accurate readings for the range of 50 kVp to 150 kVp. Four optional filter packs are available for use with the 35080M for CT, mammographic, and mobile applications.

    Specifications

    Range 50 kVp to 150 kVp, using only the wide-range radiographic filter pack (Model 37617). Range and versatility are extended with the use of special optional filter packs.
    Accuracy ± 2 % of reading in the range of 50 kVp to 150 kVp, exclusive of linearity, filtration, and gain effects. Linearity corrections automatically applied when using 35080M with either 35050AT Dosimeter or 199XRAY.
    Response time 150 μs (10 % to 90 %)
    Calibration Internally generated signal provides a calibration check.
    Minimum time for valid reading 1 ms, 3-phase; one line cycle, single-phase
    Tube Current Wide dynamic range from 4 mA to 3000 mA (3 phase), 2 mA to 1500 mA (single phase). Generator settings will vary in waveform and distance. Less than ± 1 kVp effect for wide-range radiographic filter pack covering 50 kVp to 150 kVp. Specialty filter packs may have different characteristics.
    Environmental Temperature range: 0°C to 35°C; Relative humidity: 20% to 80%; Storage temperature: -35 ºC to 50 °C
    Orientation Long axis of the Model 35080M Non-invasive kVp Divider oriented perpendicular to axis of x-ray tube to eliminate heel effect.
    Power requirements 9V batery, 60 hours operation
    Dimensions (LxWxH) 6 cm x 9 cm x 21 cm (2.38 in x 3.5 in x 8.25 in)
    Weight 0.68 kg (1.5 lb)

    Downloads...
  • Click Here to view the Users Manual For this Product.
  • Click Here to view Data Sheet For this Product.
  • Click Here to view Demo Video For this Product.




  • Stock #
    Kit Description
    Includes
    Your Price
    35080M199XRAY
    Complete 35080M and 199XRAY Package Kit Bundle.
    199XRAY Medical ScopeMeter,
    35080M Non-invasive kVp Divider,
    37617 Wide range filter pack,
    1990021004 carrying case,
    MA190 Accessory Kit.
    $12,000.00
    199XRAY
    Fluke 199XRAY, BioMedical X-Ray ScopeMeter.
    199XRAY Medical ScopeMeter,
    MA190 Accessory Kit.
    $5,618.75







    Cards We Accept!
    For order methods and policies, please click here.


    E-Mail Sales
    Telephone
    All Lines open 8-5 M-F (Pacific Time)
    Toll-Free (US): 800-827-XRAY (800-827-9729)
    Toll-Free (US): 866-PNW-XRAY (866-769-9729)
    Normal: 1-503-667-3000
    VoIP Phones / Internet Phones...
    Free World Dial-Up: 52824
    Earthlink: 07393-52824
    SIPphone: 1-393-52824
    Packet8: 0351-52824
    Broadvoice: 0110393-52824
    Download our order form
    and then...Fax Your Order
    24 Hours a day!
    503-666-8855

    P.O. Box 625 * Gresham, OR  97030 * U.S.A.

    This web site is our catalog, no printed catalog is available. - Please keep checking back, changes to this site are made daily.
    Every effort is made on our part to keep all posted prices up to date, however we can not guarantee the accuracy due to notification delays by the manufacturers.
    Purchase Orders accepted only upon approval of credit - Min. $500 opening order for new open CHARGE accounts.
    All other orders (Cash, Credit Card, etc) subject only to a $30 product minimum order!



    ©1997-2008 Pacific Northwest X-Ray Inc. - Sales & Marketing Division - All Rights Reserved