       Mammography Screen Film Contact Test Tool.       


Computerized Imaging Reference Systems, Inc! Mammography Screen Film Contact Test Tool

Features
  • Provides superior contrast
  • Easily cleaned
  • Durable construction
  • Equivalent density to 4 cm acrylic
  • Reproducable results
  • Compensators are not required
  • Minimal setup
  • Large size to cover entire cassette

  • The CIRS Model 028 Mammography Screen Film Contact Test Tool is designed for easy evaluation of mammography cassette screen to film contact. Testing process may be used on new cassettes and cassettes already in service.

    Screen film contact is directly related to mammographic image quality and image sharpness. Visualization of optimum quality images and resolution is critical while viewing microcalcifications and small masses or nodules.

    Minimal setup is required. Place the test tool on top of the cassette to be evaluated. Position the compression device as close to the x-ray tube as possible, select manual technique, or auto setting which will provide a film density between 0.70 and 0.80. Expose the film at 25 to 28 kVp. Process film as usual, and view on light box at a distance of at least 3 feet. Darker areas in the image demonstrate unacceptable screen-film contact.



    Stock #
    Description
    Your Price
    028
    Mammography Screen Film Contact Test Tool
    $194.92







    Cards We Accept!
    For order methods and policies, please click here.


    E-Mail Sales
    Telephone

    Phone Lines open...
    7am - 5pm Monday-Friday (Pacific/West Coast Time)
    8am - 6pm Monday-Friday (Mountain Time)
    9am - 7pm Monday-Friday (Central Time)
    10am - 8pm Monday-Friday (Atlantic/East Coast Time)

    Toll-Free (US): 800-827-XRAY (800-827-9729)
    Toll-Free (US): 866-PNW-XRAY (866-769-9729)
    Phone: 1-503-667-3000
    Download our order form
    and then...Fax Your Order
    24 Hours a day!
    1-503-666-8855

    P.O. Box 625 * Gresham, OR  97030 * U.S.A.

    This web site is our catalog, no printed catalog is available. - Please keep checking back, changes to this site are made daily.
    Every effort is made on our part to keep all posted prices up to date, however we can not guarantee the accuracy due to notification delays by the manufacturers.
    Purchase Orders accepted only upon approval of credit - Min. $500 opening order for new open CHARGE accounts.
    All other orders (Cash, Credit Card, etc) subject only to a $30 product minimum order!



    ©1997-2014 Pacific Northwest X-Ray Inc. - Sales & Marketing Division - All Rights Reserved