Pacific Northwest X-Ray Inc.

       Dunlee 4 inch, X-Ray Tubes for Vascular Systems.       


Dunlee, Division of Philips Medical Systems!
This 400 KHU X-Ray tube is specifically designed for general radiographic, fluoro/spot-film, angiographic, digital X-Ray systems.

General Specifications.
Tube Type: DU 404, 400 kHU (280 kJ) insert
Target Diameter: 4 in. (101.6 mm)
Target Angle: 10°
Power Characteristics: 13/70 kW
Operational Characteristics: 60/180 Hz
Focal Spot: 0.3 / 0.9
Replaces:
Shipping Weight: 65 lbs. (29.55 kg)



Warranty Term (Prorate): 24 months
Filament(s) Electrical Characteristics (Small / Large FS)
Volts: 4.5-9.0 / 5.2-13.7
Amperes: 3.0-5.5 / 3.0-5.3
Rotor/Stator Specifications.
Max Rotational Speed: 3000/9000 RPM
Main Winding Resistance: S Stator 15 ohms Q Stator 6 ohms
Secondary Winding/Shift Winding Resistance: S Stator 30 ohms Q Stator 12 ohms
Maximum Anode Cooling Rate: 1.25 kHU/sec. (890 W)


Stock #
Description
Your Price
PX1456
Complete New Tube Assembly
$6,750.00
PX1456-HC
Housing/Core Charge
$2,000.00




       Dunlee 5 inch, X-Ray Tubes for Vascular Systems.       
Dunlee, Division of Philips Medical Systems!
This 1.0 MHU X-Ray tube is specifically designed for angiographic, cath-lab, digital X-Ray systems.

General Specifications.
Tube Type: DU 1005, 1.0 MHU (710 kJ) insert
Target Diameter: 5 in. (127mm)
Target Angle: 12.5°
Power Characteristics: 44/120 kW
Operational Characteristics: 150/180 Hz
Focal Spot: 0.6 / 1.2
Replaces:
Shipping Weight: 115 lbs. (52.27 kg)





Stock #
Description
Your Price
PX1551
Complete New Tube Assembly
$12,500.00
PX1551-HC
Housing/Core Charge
$2,000.00


Warranty Term (Prorate): 12 months
Filament(s) Electrical Characteristics (Small / Large FS)
Volts: 3.0-8.5 / 4.3-12.5
Amperes: 3.0-5.5 / 3.0-5.5
Rotor/Stator Specifications.
Max Rotational Speed: 9000/10,800 RPM
Main Winding Resistance: S Stator 15 ohms / Q Stator 6 ohms
Secondary Winding/Shift Winding Resistance: S Stator 30 ohms / Q Stator 12 ohms
Maximum Anode Cooling Rate: 4 kHU/sec. (2.8 kW)




       Dunlee 5 inch, X-Ray Tubes for Vascular Systems.       
Dunlee, Division of Philips Medical Systems!
This 1.0 MHU X-Ray tube is specifically designed for angiographic, cath-lab, digital X-Ray systems.

General Specifications.
Tube Type: DU 1005, 1.0 MHU (710 kJ) insert
Target Diameter: 5 in. (127mm)
Target Angle: 10°
Power Characteristics: 14/90 kW
Operational Characteristics: 150/180 Hz
Focal Spot: 0.3 / 0.9
Replaces:
Shipping Weight: 115 lbs. (52.27 kg)





Stock #
Description
Your Price
PX1556
Complete New Tube Assembly
$12,500.00
PX1556-HC
Housing/Core Charge
$2,000.00


Warranty Term (Prorate): 12 months
Filament(s) Electrical Characteristics (Small / Large FS)
Volts: 4.5-9.0 / 5.2-13.7
Amperes: 3.0-5.5 / 3.0-5.3
Rotor/Stator Specifications.
Max Rotational Speed: 9000/10,800 RPM
Main Winding Resistance: S Stator 15 ohms / Q Stator 6 ohms
Secondary Winding/Shift Winding Resistance: S Stator 30 ohms / Q Stator 12 ohms
Maximum Anode Cooling Rate: 4 kHU/sec. (2.8 kW)




       Dunlee 5 inch, X-Ray Tubes for Vascular Systems.       


Dunlee, Division of Philips Medical Systems!
This 1.0 MHU X-Ray tube is specifically designed for angiographic, cath-lab, digital X-Ray systems.

General Specifications.
Tube Type: DU 1005, 1.0 MHU (710 kJ) insert
Target Diameter: 5 in. (127mm)
Target Angle:
Power Characteristics: 14/90 kW
Operational Characteristics: 150/180 Hz
Focal Spot: 0.3 / 0.7
Replaces:
Shipping Weight: 115 lbs. (52.27 kg)





Warranty Term (Prorate): 12 months
Filament(s) Electrical Characteristics (Small / Large FS)
Volts: 4.5-9.0 / 5.2-13.7
Amperes: 3.0-4.8 / 3.0-5.3
Rotor/Stator Specifications.
Max Rotational Speed: 9000/10,800 RPM
Main Winding Resistance: S Stator 15 ohms / Q Stator 6 ohms
Secondary Winding/Shift Winding Resistance: S Stator 30 ohms / Q Stator 12 ohms
Maximum Anode Cooling Rate: 4 kHU/sec. (2.8 kW)


Stock #
Description
Your Price
PX1557
Complete New Tube Assembly
$12,500.00
PX1557-HC
Housing/Core Charge
$2,000.00




       Dunlee 5 inch, X-Ray Tubes for Vascular Systems.       
Dunlee, Division of Philips Medical Systems!
This 1.0 MHU X-Ray tube is specifically designed for angiographic, cath-lab, digital X-Ray systems.

General Specifications.
Tube Type: DU 1005, 1.0 MHU (710 kJ) insert
Target Diameter: 5 in. (127mm)
Target Angle: 12.5°
Power Characteristics: 11/70 kW
Operational Characteristics: 150/180 Hz
Focal Spot: 0.3 / 1.0
Replaces:
Shipping Weight: 115 lbs. (52.27 kg)





Stock #
Description
Your Price
PX1558
Complete New Tube Assembly
$14,285.72
PX1558-HC
Housing/Core Charge
$2,000.00


Warranty Term (Prorate): 12 months
Filament(s) Electrical Characteristics (Small / Large FS)
Volts: 4.5-9.0 / 6.5-18.0
Amperes: 3.0-4.8 / 3.0-5.3
Rotor/Stator Specifications.
Max Rotational Speed: 9000/10,800 RPM
Main Winding Resistance: S Stator 15 ohms / Q Stator 6 ohms
Secondary Winding/Shift Winding Resistance: S Stator 30 ohms / Q Stator 12 ohms
Maximum Anode Cooling Rate: 4 kHU/sec. (2.8 kW)




       Dunlee 5 inch, X-Ray Tubes for Vascular Systems.       


Dunlee, Division of Philips Medical Systems!
This 1.0 MHU X-Ray tube is specifically designed for angiographic, cath-lab, digital X-Ray systems.

General Specifications.
Tube Type: DU 1005, 1.0 MHU (710 kJ) insert
Target Diameter: 5 in. (127mm)
Target Angle: 10°
Power Characteristics: 50/100 kW
Operational Characteristics: 150/180 Hz
Focal Spot: 0.6 / 1.0
Replaces:
Shipping Weight: 115 lbs. (52.27 kg)



Warranty Term (Prorate): 12 months
Filament(s) Electrical Characteristics (Small / Large FS)
Volts: 3.0-8.5 / 5.2-13.7
Amperes: 3.0-5.5 / 3.0-5.5
Rotor/Stator Specifications.
Max Rotational Speed: 9000/10,800 RPM
Main Winding Resistance: S Stator 15 ohms / Q Stator 6 ohms
Secondary Winding/Shift Winding Resistance: S Stator 30 ohms / Q Stator 12 ohms
Maximum Anode Cooling Rate: 4 kHU/sec. (2.8 kW)


Stock #
Description
Your Price
PX1559
Complete New Tube Assembly
$12,500.00
PX1559-HC
Housing/Core Charge
$2,000.00




       Dunlee 5 inch, X-Ray Tubes for Vascular Systems.       
Dunlee, Division of Philips Medical Systems!
This 1.5 MHU X-Ray tube is specifically designed for use with Picker CV Pro cardiovascular X-Ray systems.

General Specifications.
Tube Type: DU 1505, 1.5 MHU (1.06 MJ) insert
Target Diameter: 5 in. (127mm)
Target Angle: 10°
Power Characteristics: 50/100 kW
Operational Characteristics: 150/180 Hz
Focal Spot: 0.6 / 1.0
Replaces:
Shipping Weight: 115 lbs. (52.27 kg)








Stock #
Description
Your Price
PX1572
Complete New Tube Assembly
$17,187.50
PX1572-HC
Housing/Core Charge
$3,000.00


Warranty Term (Prorate): 12 months
Filament(s) Electrical Characteristics (Small / Large FS)
Volts: 3.0-8.5 / 7.7-13.7
Amperes: 3.0-5.5 / 3.0-5.3
Rotor/Stator Specifications.
Max Rotational Speed: 9000/10,800 RPM
Main Winding Resistance: S Stator 15 ohms / Q Stator 6 ohms
Secondary Winding/Shift Winding Resistance: S Stator 30 ohms / Q Stator 12 ohms
Maximum Anode Cooling Rate: 4 kHU/sec. (2.8 kW)







Cards We Accept!
For order methods and policies, please click here.


E-Mail Sales
Telephone
All Lines open 8-5 M-F (Pacific Time)
Toll-Free (US): 800-827-XRAY (800-827-9729)
Toll-Free (US): 866-PNW-XRAY (866-769-9729)
Normal: 1-503-667-3000
VoIP Phones / Internet Phones...
Free World Dial-Up: 52824
Earthlink: 07393-52824
SIPphone: 1-393-52824
Packet8: 0351-52824
Broadvoice: 0110393-52824
Download our order form
and then...Fax Your Order
24 Hours a day!
503-666-8855

P.O. Box 625 * Gresham, OR  97030 * U.S.A.

This web site is our catalog, no printed catalog is available. - Please keep checking back, changes to this site are made daily.
Every effort is made on our part to keep all posted prices up to date, however we can not guarantee the accuracy due to notification delays by the manufacturers.
Purchase Orders accepted only upon approval of credit - Min. $500 opening order for new open CHARGE accounts.
All other orders (Cash, Credit Card, etc) subject only to a $30 product minimum order!



©1997-2008 Pacific Northwest X-Ray Inc. - Sales & Marketing Division - All Rights Reserved